Burning natural gas in a boiler, furnace or engine you control is a Scope 1 emission. The two official sets imported on this site publish different units and different gases, so pick the one that matches your country and your meter reading.

UK: DESNZ conversion factors 2026

The UK Government conversion factors are published by the Department for Energy Security and Net Zero (DESNZ). The methodology paper notes that the set was previously known as the “Defra/DECC” GHG conversion factors. Values are in kg CO2e (CO2, CH4 and N2O combined by DESNZ).

Unit of your activity dataFactor (combustion, Scope 1)Upstream (well-to-tank, Scope 3)
kWh (Gross CV)0.18231 kg CO2e per kWh (Gross CV)0.03021 kg CO2e per kWh (Gross CV)
kWh (Net CV)0.20199 kg CO2e per kWh (Net CV)0.03347 kg CO2e per kWh (Net CV)
cubic metres2.02633 kg CO2e per cubic metres0.3366 kg CO2e per cubic metres
tonnes2,507.7 kg CO2e per tonnes423.164 kg CO2e per tonnes

Gross or net CV? The same gas has two energy values. Gross calorific value counts the heat in the water vapour produced; net calorific value does not, so a kWh figure on a net basis is smaller and its factor is larger. The DESNZ methodology paper says UK suppliers generally quote natural gas kWh on a gross basis, so use the Gross CV factor unless your supplier says it used net CV. Example: 50,000 kWh (Gross CV) × 0.18231 ≈ 9,115.5 kg CO2e.

Well-to-tank factors cover the emissions upstream of the point of use: extraction, transport, processing and distribution of the gas. DESNZ classes them as Scope 3. Report them separately from the combustion figure; do not add them into Scope 1.

The set also has rows labelled “Natural gas (100% mineral blend)”; check the methodology paper before choosing them. See the UK dataset page or search for natural gas for all rows.

US: EPA GHG Emission Factors Hub 2025

The EPA Hub publishes stationary-combustion factors per gas, not as CO2e, and this site keeps them separate.

UnitCO2CH4N2O
mmBtu53.06 kg CO2 per mmBtu0.001 kg CH4 per mmBtu0.0001 kg N2O per mmBtu
scf (standard cubic foot)0.05444 kg CO2 per scf0.00000103 kg CH4 per scf1e-7 kg N2O per scf

To report CO2e from these, multiply each gas by the global warming potential your reporting framework requires and add them up; this site does not choose GWPs for you (see CO2 vs CO2e).

Limitations

Sources