Natural gas emission factors: UK (DESNZ) and US (EPA) values
Updated 2026-10-17
Burning natural gas in a boiler, furnace or engine you control is a Scope 1 emission. The two official sets imported on this site publish different units and different gases, so pick the one that matches your country and your meter reading.
UK: DESNZ conversion factors 2026
The UK Government conversion factors are published by the Department for Energy Security and Net Zero (DESNZ). The methodology paper notes that the set was previously known as the “Defra/DECC” GHG conversion factors. Values are in kg CO2e (CO2, CH4 and N2O combined by DESNZ).
| Unit of your activity data | Factor (combustion, Scope 1) | Upstream (well-to-tank, Scope 3) |
|---|---|---|
| kWh (Gross CV) | 0.18231 kg CO2e per kWh (Gross CV) | 0.03021 kg CO2e per kWh (Gross CV) |
| kWh (Net CV) | 0.20199 kg CO2e per kWh (Net CV) | 0.03347 kg CO2e per kWh (Net CV) |
| cubic metres | 2.02633 kg CO2e per cubic metres | 0.3366 kg CO2e per cubic metres |
| tonnes | 2,507.7 kg CO2e per tonnes | 423.164 kg CO2e per tonnes |
Gross or net CV? The same gas has two energy values. Gross calorific value counts the heat in the water vapour produced; net calorific value does not, so a kWh figure on a net basis is smaller and its factor is larger. The DESNZ methodology paper says UK suppliers generally quote natural gas kWh on a gross basis, so use the Gross CV factor unless your supplier says it used net CV. Example: 50,000 kWh (Gross CV) × 0.18231 ≈ 9,115.5 kg CO2e.
Well-to-tank factors cover the emissions upstream of the point of use: extraction, transport, processing and distribution of the gas. DESNZ classes them as Scope 3. Report them separately from the combustion figure; do not add them into Scope 1.
The set also has rows labelled “Natural gas (100% mineral blend)”; check the methodology paper before choosing them. See the UK dataset page or search for natural gas for all rows.
US: EPA GHG Emission Factors Hub 2025
The EPA Hub publishes stationary-combustion factors per gas, not as CO2e, and this site keeps them separate.
| Unit | CO2 | CH4 | N2O |
|---|---|---|---|
| mmBtu | 53.06 kg CO2 per mmBtu | 0.001 kg CH4 per mmBtu | 0.0001 kg N2O per mmBtu |
| scf (standard cubic foot) | 0.05444 kg CO2 per scf | 0.00000103 kg CH4 per scf | 1e-7 kg N2O per scf |
To report CO2e from these, multiply each gas by the global warming potential your reporting framework requires and add them up; this site does not choose GWPs for you (see CO2 vs CO2e).
Limitations
- The UK factors describe UK gas supply and the US factors US supply. Neither is a default for other countries.
- The UK and US values are not directly comparable: different gases (CO2e vs separate gases), units and energy bases.
- The year shown is the edition of each set, not the year of the underlying data; the methodology documents explain the data years.
Sources
- UK Government GHG Conversion Factors for Company Reporting (dataset page on this site) (Data on this site)
- DESNZ — Greenhouse gas reporting: conversion factors 2026 (Primary source)
- DESNZ — 2026 Government greenhouse gas conversion factors for company reporting: methodology paper (paragraphs 1.4, 2.9, 2.11) (Primary source)
- US EPA GHG Emission Factors Hub (dataset page on this site) (Data on this site)
- US EPA — GHG Emission Factors Hub (Primary source)